Product Details:
Brand | V TECH |
Display Type | Digital |
Product Details:
Minimum Order Quantity | 1 Number |
Brand | vtech |
Gas Type | Combustible Gas, Natural Gas |
Detector Features | Battery Back-Up |
Display Type | Digital, Analog, Graphics |
Power Source | Battery, Plug-In |
In line with clients' diverse requirements across the country, we are offering an excellent range of Methane Gas Monitor. This monitor is designed at our advanced manufacturing unit using the best quality components and latest technology in conformance with defined quality standards. It is used to industrial hygienists, occupational health and safety personnel and indoor air quality professionals to assess air quality in the workplace in accordance with state and national guidelines. Being a quality-oriented organization, we assure our clients that this monitor is excellent on counts of durability and quality.
Features:
Application:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | V TECH |
Display Type | Digital |
Product Details:
Minimum Order Quantity | 1 Number |
Maximum capacity (Gram) | 12 kg/cm2 |
Model | 303D |
Temperature range (Degree Celsius) | -60+30 Deg C |
Display Type | Digital |
Automatic Grade | Manual |
Model ATS-303D Process Moisture Analyzer Designed to Handle Rigorous Demands of Moisture Measurement in Natural Gas Applications, Provides Fully Automatic Self-Calibration Dew Point System, Provides Cost Effective Solution for Demanding and Critical Moisture Monitoring Applications.
The advantages of a linear high capacitance response are: better sensitivity, better repeatability and faster response times. Also, the measurement system is less prone to noise and drift, and signal conditioning is kept to a minimum.
The dew point meter is operated through a menu driven user interface consisting of a custom LCD display with backlight, and four push buttons.
This dew point system has proven to produce consistently accurate monitoring results for dew point in natural gas and other difficult hydrocarbon processing applications, where conventional analyzers have failed.
Specification :
Principle Thin Film Capacitive, Capacitive Aluminum Oxide Range Degree C, PPM % RHResolution0.1 Unit or 1 Unit (Application based)Sampling Method Direct Plug InDisplay128 X 64 Graphics LCDPower Source Built in Lithium Rechargeable battery Or 230V AC Accuracy+/2%Response Time Data Storage5000 or 10000Computer Interface RS 232, USB Analog Output4-20mASensor Life2-3 YearsTemperature15degree Celsius Humidity< 85%RH Atmosphere Pressure86- 106KpaHousingHigh Impact Plastic Dimension in mm200 (W) X 120 (H) X 185(D)Weight1.5 KG Warranty One Year
RequestAdditional Information:
Product Details:
Brand | V TECH |
Usage/Application | Industrial |
Display Type | Digital |
Package include:
Additional Information:
Product Details:
Model Name/Number | V TECH |
Display | Local |
Product Details:
Brand | V TECH |
Display Type | Digital |
Usage/Application | Gas Detection |
Power Source | Battery |
Resolution | 1PPM |
Accuracy | +-5% or +-10 PPM |
Range | 0 to 1000PPM |
Warm up period | <2 seconds |
Max Hold and Data Hold Facility
Display Backlit LCD
Range 0 to 1000PPM
Resolution 1PPM
Accuracy ±5% or ±10 PPM
Warm up period <2 seconds
Auto Power off
Product Details:
Brand | V TECH |
Usage/Application | Industrial |
Display Type | Digital |
Power Source | Battery |
Product Details:
Brand | V TECH |
Product Details:
Minimum Order Quantity | 50 Unit |
Brand | Applied Techno Systems |
Model | ATS 109TD |
Condition | New |
Voltage (V) | 230V |
Digital Output | 4-20mA |
Range (mm) | 0-2000 PPM |
Accuracy (%) | +/-2%. |
Warranty | One Year |
Is It Portable | Non Portable |
Sensors | Electrochemiccal (EC) |
Single Channel | Yes |
Sulfur Dioxide Gas Sensor Tranmsitter
The ATS-109TD Sensor/Transmitter with without Display operates on 24 VDC power and 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.
The ATS-109TD Sulfur dioxide (SO2 Sensor/Transmitters utilize electrochemical type cells to detect the target gas. These cells consist of electrodes, electrolyte and an air/liquid separation barrier. Gas molecules enter the cell and, as a result of an oxidation/reduction reaction, generate an electrical current proportional to the gas concentration
Specification
Accuracy +/-2%. Sampling Diffusion Power Supply 230V AC from Control Unit Housing Flameproof Group IIA/IIB Output 4-20mA for PLC/SCADA |
Additional Information:
Product Details:
Brand | V TECH |
Additional Information:
Product Details:
Brand | V TECH |
Gases Detected | Methane |
Operating Voltage | DC 5 Volt |
Size | 32mm X 22mm X 27mm |
Usage/Application | Industrial |
The main chip | LM393,ZYMQ-4 gas sensor |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model / Part Number | MQ-7 |
Target gases | Carbon Monoxide |
Operating Voltage | 5V |
Output Current ( in mA) | 150mA |
Dimensions | 33(L) * 21(W) * 17(H) mm |
Response Time | <=1 sec |
Display Type | Digital, Analog |
Product Details:
Usage/Application | Industrial |
Brand | V TECH |
Product Details:
Minimum Order Quantity | 1 Number |
Band pass Filter Bandwidth | 170nm to 810nm |
Connectivity | Real time |
Environment | Water |
Frequency | 10 min |
Measuring Principle | UV |
Number Of Methods | one |
Product Details:
Usage/Application | Laboratory |
Product Details:
Minimum Order Quantity | 1 Piece |
Color | Blue Grey |
Product Type | Fixed Type |
Features | Graphics Display with RS 485 mod bus output |
Range | PPM,mg/Nm3,V/V |
Application | stack,Boiler,Heat treatment,incinerator etc |
Automation Grade | Automatic |
Model | 208 A |
Brand | V TECH |
Display Type | Graphics Display |
Display | 320 x 260 |
Additional Information:
Additional Information:
Product Details:
Brand | V TECH |
Response Time CO2:
Product Details:
Usage/Application | Industrial |
Brand | V TECH |
Product Details:
Minimum Order Quantity | 1 Number |
Display Type | Digital |
Brand | Dynoptic |
Application | Industrial |
Model | DSL 340 |
Material | 316 Stainless Steel (powder coated) |
Measuring Principle | Dynamic Detection Principle, DDP (Scintillation) |
Accuracy | + / - 2 % |
Digital Output | USB RS- 485/ RS-232 |
Dimension | 153 x 120 x 122 mm (measuring head) |
Ambient Operating Temperature | -20-+55 Deg C air temperature around the equipment |
Additional Information:
Product Details:
Brand | V Tech |
Product Details:
Brand | V TECH |
Automation Grade | Automatic |
Product Details:
Minimum Order Quantity | 50 Unit |
Brand | Applied Techno Systems |
Model | 208A |
Color | Grey |
Application | Industrial Use |
Product Type | Analyzer |
Features | Controller |
Range | 0-1000 mg/Nm3 |
Automation Grade | Automatic |
Display Type | 128x64 Graphic Display |
Display | 128*64 Graphics |
Response Time | less than 30 Sec |
Weight | 600 |
Power | 230 V AC 50 Hz |
Temperature | -5 to 55 deg C |
Humidity | 0-95% RH |
Measurement Gas Pressure | 1.5Kg/cm2 |
Measuring Range | PPM % V/V |
Source Voltage 90 | 5 V |
Sample Gas Flow | 1.5LPM |
Power Supply | 3.7 V lithium |
Make | V TECH |
Output Signal | RS-485/232 |
Operating Temp Deg Celsius | -5 to +55 Deg C |
Additional Information:
Product Details:
Brand | V TECH |
Usage/Application | Industrial |
Automation Grade | Automatic |